42
5. Select a line thickness from the right column.
6. Tap
Done
to save the settings and exit, or tap
Cancel
to exit without saving.
NOTE
In full screen display mode, you can edit the waveform color and line thickness by tapping
the
Edit
button on the top-right side of the screen.
Trigger Settings
On the Trigger Settings screen, you can set a standard range by filling in minimum and
maximum values. When exceeding these values, the trigger function will be executed and
the device will automatically record and save the generated data. You can review the
saved live data by tapping the
Review
button at the bottom of the screen.
Tap the drop-down menu to the right of a parameter to open a submenu. The
Trigger
button is the last one in the submenu. Tap to display the Trigger Settings window.
Figure 4-22
Trigger Setting Screen
Two buttons and two input boxes are available in the Trigger Settings window.
a) Trigger
— toggles the trigger on and off. The trigger is ON by default.
b) Buzzer Alarm
— switches the alarm on and off. The alarm function makes a beeping
sound as an alert when the data reading reaches the preset minimum or maximum
value. The buzzer alarm will only sound at the first trigger.
c) MIN
— tap this input box to display a virtual keyboard to enter a lower threshold value.
d) MAX
— tap this input box to display a virtual keyboard to enter an upper threshold
value.