EMS Alarm Guide
58
Document #: 94602
EMS
3.2.30 Power
Supply
Alarm
Table 3-29: Power Supply Alarm
Description
Generated if either:
The HA (High Availability) feature is active and one of the power
supply units is faulty or missing.
PS unit is inserted in its location and functioning.
SNMP Alarm
acPowerSupplyAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.30
Alarm Title
Power Supply Alarm
Alarm Source
Chassis#0/PowerSupply#<m> where m is the power supply’s slot
number
Alarm Type
Equipment
Alarm
Probable Cause
Power
problem
Severity
Major
Clear
Additional Info
-
Corrective Action
-
3.2.31 PEM
Alarm
Table 3-30: PEM Alarm
Description
Generated if either:
The HA (High Availability) feature is active and one of the PEM
(Power Entry Module) units is missing
PEM card is in its location and both DC wires are in.
SNMP Alarm
acPEMAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.31
Alarm Title
PEM Module Alarm
Alarm Source
Chassis#0/PemCard#<m> where m is the power entry module’s slot
number
Alarm Type
equipmentAlarm
Probable Cause
underlyingResourceUnavailable
Severity
Critical
Clear
Additional Info
-
Corrective Action
-