Version 3.2
43
October 2007
EMS Alarm Guide
3. Mediant 1000/2000/3000, IPmedia 2000/3000 and MediaPack Alarms
3.2.4 Initialization
Ended
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the device have the same standard structure,
including the fields shown in the table.
Table 3-6: Initialization Ended
Description
Sent when the device is initialized and ready to run
SNMP Alarm
acBoardEvBoardStarted
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.4
Alarm Title
Initialization Ended
Alarm Type
Equipment Alarm
Alarm Source
Probable Cause
Other
Severity
Major
Additional Info
NULL
3.2.5 Board
Resetting
Following Software Reset
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the device have the same standard structure,
including the fields shown in the table.
Table 3-7: Board Resetting Following Software Reset
Description
The device started the reset process - following software reset
SNMP Alarm
acBoardEvResettingBoard
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.5
Alarm Title
Board Resetting Following Software Reset
Alarm Type
Other
Alarm Source
Probable Cause
Other
Severity
Critical
Additional Info
'AdditionalInfo1', 'AdditionalInfo2', 'AdditionalInfo3',
Corrective Action
A network administrator has taken action to reset the device. No
corrective action is needed.