EMS Alarm Guide
30
Document #: 94602
EMS
Table 2-8: Fan Alarm
Description
Fan (location description) speed [is out of nominal range (Active alarm),
[returned to nominal range (Cleared alarm)]
SNMP Alarm
tgFanAlarm
SNMP OID
1.3.6.1.4.1.5003.9.1.2.2.0.9
Alarm Title
Fan Alarm
Alarm Source
SAT/Fan (location description)
Alarm Type
Equipment Alarm
Probable Cause
Power problem
Severity
Mediant 8000: Minor, Major or Cleared
Mediant 5000: Critical when the large front fan fails.
Additional Info
Info 1: Measured fans speed: FL=yyy, FR=xxx, RL=zzz (Mediant 8000
chassis abbreviations: Front Left, Front Right, Rear Left, Rear Right. The
abbreviations for the Mediant 5000 are similar.
Info 2: 'Crossed Threshold = Fx', Configured thresholds: F1, F2, F3, F4
Corrective Action
If the alarm is set, check the chassis air filter.
2.10 Temperature
Alarm
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the Media Gateway have the same standard
structure, including the fields shown in the table.
Table 2-9: Temperature Alarm
Textual Description
Planned for the future.
SNMP OID
1.3.6.1.4.1.5003.9.1.2.2.0.10
2.11 Ethernet External Link Alarm
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the Media Gateway have the same standard
structure, including the fields shown in the table.