Table 2-16: Board Diagnostics Alarm
Description
Indicates that the board's health diagnostics tests have failed/solved
TP-1610/TP-6310/ES/SC health diagnostics test failed - failure alarm
TP-1610/TP-6310/ES/SC health diagnostics failure cleared - for cleared
alarm
SNMP Alarm
tgBoardDiagnosticsAlarm
SNMP OID
1.3.6.1.4.1.5003.9.1.2.2.0.29
Alarm Title
Board Diagnostics Alarm
Alarm Source
Board#
Alarm Type
Equipment failure
Probable Cause
Equipment malfunction
Severity
Major for fails, Cleared when changed to normal
Additional Info
Info 1: Fault Element: [string from the list of board's components -
ElementID in the case of TP, including its index]
Info 2: Test Initiative: [Board Startup Diagnostics, PeriodicDiagnostics,
User Initiated Diagnostics]
Initial Test State: [list of standing alarms, clear of alarms]
Corrective Action
If set, restart the board with a lock and unlock sequence. If the alarm
repeats, extract and insert the board again into the chassis. If the alarm
continues, report to the service center.