Version 3.2
63
October 2007
EMS Alarm Guide
3. Mediant 1000/2000/3000, IPmedia 2000/3000 and MediaPack Alarms
3.2.39 SONET Section LOS Alarm
Table 3-38: SONET Section LOS Alarm
Description
LOS or AIS condition is present on SONET no #m.
The field ‘sonetSectionCurrentStatus’ in the sonetSectionCurrentTable
will have a value of sonetSectionLOS (2).
SNMP Alarm
acSonetSectionLOSAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.39
Alarm Title
SONET Section LOS Alarm
Alarm Source
Interfaces#0/Sonet#<m> where m is the SONET I/F number
Alarm Type
Communications Alarm
Probable Cause
Loss of signal
Severity
Critical on raise, Clear on clear
Additional Info
-
Corrective Action
-
3.2.40 SONET Line AIS Alarm
Table 3-39: SONET Line AIS Alarm
Description
AIS condition is present on SONET-Line #m.
The field ‘sonetLineCurrentStatus’ in the sonetLineCurrentTable will have
a value of sonetLineAIS (2).
SNMP Alarm
acSonetLineAISAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.40
Alarm Title
SONET Line AIS Alarm
Alarm Source
Interfaces#0/Sonet#<m> where m is the SONET I/F number
Alarm Type
Communications Alarm
Probable Cause
Receive Failure
Severity
Critical on raise, Clear on clear
Additional Info
-
Corrective Action
-