Version 3.2
27
October 2007
EMS Alarm Guide
2. Mediant 5000, 8000 Alarms
2.6 Configuration
Error
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the Media Gateway have the same standard
structure, including the fields shown in the table.
Table 2-5: Configuration Error
Description
This trap is issued when a configuration error or configuration
inconsistency is caused by the User (via the EMS or MIB Browser). It's a
general alarm. The problem description is provided in the 'text' form
(AdditionalInfo).
SNMP Alarm
tgConfigurationError
SNMP OID
1.3.6.1.4.1.5003.9.1.2.2.0.6
Alarm Title
Configuration Error
Alarm Source
MO Path
Alarm Type
Processing error alarm
Probable Cause
Configuration or customization error
Severity
Indeterminate
Additional Info
String explaining a certain problem in configuration or data inconsistency.
Examples:
'Redundant board is configured as Normal board'
'Data of the SC is corrupted. Parameter name'
Corrective Action
For a set alarm, correct the configuration using the guidelines contained
in the field 'Additional Info'.
2.7 Operational
Info
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the Media Gateway have the same standard
structure, including the fields shown in the table.
Summary of Contents for LTRT-94602