Version 3.2
33
October 2007
EMS Alarm Guide
2. Mediant 5000, 8000 Alarms
2.14 Push
Button
Alarm
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the Media Gateway have the same standard
structure, including the fields shown in the table.
Table 2-13: Push Button Alarm
Description
Alarms relays manually deactivated.
SNMP Alarm
tgPushButtonAlarm
SNMP OID
1.3.6.1.4.1.5003.9.1.2.2.0.14
Alarm Title
Push Button Alarm
Alarm Source
SAT/Pushbutton [Cutoff] [Switchover]
Alarm Type
equipmentAlarm
Probable Cause
Pushbutton pressed
Severity
Informational
Additional Info
Info 1: Cutoff case. Previous state of alarm relays: Minor = open/connect,
Major = o/c, Critical = o/c
Info 2: Cutoff case. Previous state of alarm LEDs: Minor = Red/Green,
Major = Red/Yellow and Critical = Red/Blue
Corrective Action
N/A