Version 3.2
15
October 2007
EMS Alarm Guide
1. EMS Alarms
1.7 Configuration
Mismatch
Table 1-7: Configuration Mismatch
Textual Description
Generated when the EMS detects a configuration mismatch between
the actual parameter values provisioned and previous parameter
values provisioned.
SNMP OID
1.3.6.1.4.1.5003.9.20.3.2.0.7
AlarmTitle
Configuration Mismatch
ItuAlarmType
Equipment Alarm
AlarmSource
Media Gateway
Probable Cause
Software Error
Severity
Warning
Additional Info
-
Corrective Action
Run Configuration Verification command in order to compare EMS
configuration and actual MG configuration:
MG configuration is wrong
: use configuration download to
update MG with correct configuration saved in EMS database.
MG is correct, EMS is not updated
: use configuration upload to
save a correct MG configuration in the EMS database.
Check the Actions Journal for recent updates of the gateway.
Media Gateways
MediaPacks, Mediant 1000, Mediant 2000, IPmedia 2000, Mediant
3000, IPmedia 3000
Summary of Contents for LTRT-94602