EMS Alarm Guide
56
Document #: 94602
EMS
3.2.25 SS7 Node Operational State Changed
Table 3-25: SS7 Node Operational State Changed
Description
SS7 SN Set State Change Alarm. Alarm is raised when status is BUSY,
and cleared when status is OFFLINE, or INSERVICE.
*** SS7 *** SP # i is < 'BUSY','OFFLINE', 'INSERVICE'>
SNMP Alarm
acSS7SNSetStateChangeAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.25
Alarm Title
SS7 SN Set State Change Alarm
Alarm Type
communicationsAlarm
Alarm Source
SS7/SP#
Probable Cause
other
Severity
Major on raise condition, Clear
Additional Info
-
Corrective Action
Signaling Node must complete its MTP3 restart procedure and become
un-isolated
3.2.26
SS7 Redundancy Alarm
Support for this alarm is pending.
3.2.27 Threshold
of
Performance
Monitored Object Exceeded
Table 3-26: Threshold of Performance Monitored Object Exceeded
Description
This alarm raised when a performance counter has crossed the high / low
threshold.
'Performance: Threshold alarm was set', with source = name of the
performance counter which caused the trap
SNMP Alarm
acPerformanceMonitoringThresholdCrossing
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.27
Alarm Title
Performance Monitoring Threshold Crossing
Alarm Type
Other
Alarm Source
MO Path
Probable Cause
Other
Severity
Indeterminate (this is a notification; it's not automatically cleared)
Additional Info
-
Corrective Action
-
Summary of Contents for LTRT-94602