![Atlas Copco ZR 110 Instruction Book Download Page 75](http://html.mh-extra.com/html/atlas-copco/zr-110/zr-110_instruction-book_3001728075.webp)
Minimum
setting
Factory
setting
Maximum
setting
Oil pressure (shut-down level)
bar(e)
1.0
1.2
1.9
Oil pressure (shut-down level)
psig
14.5
17.4
27.6
Delay at starting (oil pressure)
sec
15
15
20
Service settings
Minimum
setting
Factory
setting
Maximum
setting
Drive motor regreasing time (running
hours)
hr
0
See
--
Oil filter lifetime (running hours)
hr
0
8000
--
Oil lifetime (running hours)
hr
0
16000
--
Fixed settings
Minimum
setting
Factory
setting
Maximum
setting
Delay at signal
sec
0
60
255
Terminology
Term
Explanation
Compressor
element 1/2
Element 1 and element 2 stands for the low-pressure and high-pressure compressor
element respectively.
The regulator does not accept illogical settings, e.g. if the warning level is programmed
at 210˚C, the minimum limit for the shut-down level changes into 211˚C. The
recommended difference between the warning level and shut-down level is 10 ˚C.
Compressor
element 1/2
Element 1 and element 2 stands for the low-pressure and high-pressure compressor
element respectively.
The regulator does not accept illogical settings, e.g. if the warning level is programmed
at 410 ˚F, the minimum limit for the shut-down level changes into 411 ˚F. The
recommended difference between the warning level and shut-down level is 18 ˚F.
Oil
Use Atlas Copco Roto-Z oil. The change interval for this oil is after 16000 running hours
or 2-yearly.
Oil filters
Use Atlas Copco filters. The change interval is after 8000 running hours or yearly.
Air filters
Use Atlas Copco filters. Replace the filters when the warning level is reached or yearly.
Required stop
period/Minimum
stop time
Once the compressor is automatically stopped, it will remain stopped for the minimum
stop time (approx. 20 seconds), whatever happens with the air net pressure. In
automatic operation, the compressor will not be stopped by the regulator until a
standstill period of at least the sum of the minimum stop time and required stop period is
expected. However, if the decrease in air net pressure should require a new start of the
compressor, the regulator will start the compressor after the minimum stop time.
Power recovery
time
Is the period within which the voltage must be restored to have an automatic restart. Is
accessible if the automatic restart is activated. To activate the automatic restart function,
consult Atlas Copco.
Instruction book
2920 1815 04
73
Summary of Contents for ZR 110