• Push the Enter key; the low band setting becomes highlighted. Push the Enter key to modify the
on/off setting or use the arrow down key to modify the low setting.
• Push the Enter key to confirm the modification.
• Proceed to modify the high band setting.
6.18 Programmable settings
Service settings
Factory
setting
Service
Service level A
hr
4000
Service level B
hr
8000
Service level C
hr
16000
Service level D
hr
40000
Service level E
hr
60000
Service level I
hr
2000
Remark
A number of service operations are grouped (Level A, Level B, ...). Each level stands for a number of
service operations to be carried out at the programmed intervals. Consult your Atlas Copco Service Center.
Other programmable settings
Unit
Min.
(Pack
version)
Min.
(Full-
Feature
version)
Max.
Max. (with
Energy
Recovery)
Pressure regulation (UN)LOAD level
mbar
7 bar (60 Hz )
4000
5000
7005
6505
7.5 bar (50 Hz)
4000
5500
7505
7005
8.6 bar (50 Hz)
4000
6500
8605
8105
8.6 bar (60 Hz)
4000
6500
8605
8105
10 bar (50 Hz)
7000
7500
10005
9505
10.4 bar (60 Hz)
7000
7500
10405
9905
13 bar (50 Hz)
7000
9500
13005
12505
13 bar (60 Hz)
7000
9500
13005
12505
=>converted (m)bar-psi values
psi
* 101.5 psi (60 Hz)
58.0
72.5
101.6
94,3
* 108.7 psi (50 Hz)
58.0
79.8
108.9
101.6
* 125 psi (50 Hz)
58.0
94.3
124.8
117.6
Instruction book
164
2920 1815 04
Summary of Contents for ZR 110
Page 2: ......
Page 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Page 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Page 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Page 326: ......
Page 327: ......