3.25 Unload-load menu
Control panel
Function
To load and unload the compressor manually.
Normally, the compressor is running in automatic operation, i.e. loading, unloading, stopping and
automatic restarting. LED (1) is then alight.
If required, the compressor can be unloaded manually: the compressor will run unloaded unless it is loaded
again manually.
Manually unloading
Starting from the Main screen (see
): press key Unload (2). LED (1) goes out. The
message “Manually Unloaded” appears on the display.
Manually loading
Starting from the Main screen (see
): press key Load (2). LED (1) lights up.
Note
The compressor is not forced to loaded condition, but the operation of the compressor is
switched to automatic operation again and will be loaded if required by the air net pressure.
3.26 Programmable settings
Regulation settings
Minimum
setting
Factory
setting
Maximum
setting
Motor running time in star
sec
10
15
30
Load delay time (star-delta)
sec
10
10
30
Instruction book
70
2920 1815 04
Summary of Contents for ZR 110
Page 2: ......
Page 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Page 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Page 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Page 326: ......
Page 327: ......