![Atlas Copco ZR 110 Instruction Book Download Page 308](http://html.mh-extra.com/html/atlas-copco/zr-110/zr-110_instruction-book_3001728308.webp)
Supply voltage
(V)
Recommended overload setting F21
(A)
380
138.6
440
120.6
460
110.2
575
88.0
ZT/ZR 110 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380
137
440
119
460
113
575
91
ZT/ZR 110 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380
180.1
440
155.9
460
149.6
575
119.9
ZT/ZR 110 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380
168
440
143
460
137
575
110
ZT/ZR 110 compressors with oversized IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380
180.1
440
155.9
460
149.6
575
119.9
ZT/ZR 110 compressors with oversized IE3 motor