![Atlas Copco ZR 110 Instruction Book Download Page 232](http://html.mh-extra.com/html/atlas-copco/zr-110/zr-110_instruction-book_3001728232.webp)
Electric connections for compressors without a starter (Model year 2014)
Text on figures
Reference
Text on figure
(1)
Customer’s installation
(2)
K21, K23 larger than or equal to 56 with 6 type “2” fuses
(3)
K21, K23 larger than or equal to 56 with 3 type “1” fuses
(4)
K21, K23 smaller than 56 with 3 type “2” fuses
(5)
Compressor motor
(6)
Fan motor, dryer, not for ZR compressors
(7)
Fan motor, not for ZR compressors
(8)
Fan motor, only for units without compressor motor
(9)
To be installed by the customer
(10)
Dryer heater
(11)
Connection only to be made for CSA/UL
(12)
Fan motor in motor hood of ZR/ZT without a motor
(13)
Wound anti-clockwise low-pressure side
(14)
Wound anti-clockwise high-pressure side
(15)
Main motor
Instruction book
230
2920 1815 04
Summary of Contents for ZR 110
Page 2: ......
Page 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Page 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Page 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Page 326: ......
Page 327: ......