Supply voltage
(V)
Recommended overload setting F21
(A)
380
169
400
159
500
128
690
93
ZT/ZR 145 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380
166.0
400
159.3
500
127.5
690
92.3
ZT/ZR 145 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380
156
400
147
500
118
690
86
ZR/ZT 160 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE2 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380
189
400
183
500
146
690
106
ZR/ZT 160 compressors designed for a maximum inlet temperature of 40 ˚C/104 ˚F with IE3 motor
Supply voltage
(V)
Recommended overload setting F21
(A)
380
199
400
189
500
153
690
109
ZR/ZT 160 compressors designed for a maximum inlet temperature of 50 ˚C/122 ˚F with IE2 motor
or equipped with oversized IE2 motor
Instruction book
302
2920 1815 04
Summary of Contents for ZR 110
Page 2: ......
Page 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Page 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Page 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Page 326: ......
Page 327: ......