Compressors designed for a maximum ambient temperature of 50 °C (122 °F) with IE3 motors or
with oversized motors
Type
FLA
MCA
Proposed cable
(mm²)
Maximum
cable
length (m)
Proposed
fuses (A)
(gL/gG)
Maximum
fuse (A)
(gL/gG)
Icc
ZT/ZR 110
264
291
4 X (3 X50+25)
156
2 x(3 X 200) 315
50 kA
ZT/ZR 132
285
314
2 X (3 X150+95)
318
2 x(3 X 250) 400
50 kA
ZT/ZR 145
285
314
2 X (3 X150+95)
318
2 x(3 X 250) 400
50 kA
ZT/ZR 160
409
450
4 X (3 X 95+50)
177
2 x(3 X 315) 400
50 kA
ZT/ZR 200
515
567
4 X (3 X 150+95)
226
2 x(3 X 400) 500
50 kA
ZT/ZR 250
623
686
4 X (3 X 185+95)
207
2 x(3 X 500) 500
50 kA
FLA and MCA based on an air-cooled full option compressor.
Icc only achieved with recommended fuses.
400 V - 50 Hz IEC
Compressors designed for a maximum ambient temperature of 40 °C (104 °F) with IE2 motors
Type
Cables (H07V2-K) IEC 60364-5-52:
E & 4
mm
2
Fuses gL/gG
(A)
Maximum cable length
(m)
ZR/ZT 110
2 x (3x 120 + 70)
2X (3X 250)
260
ZR/ZT 132
2 x (3x 120 + 70)
2X (3X 250)
260
ZR/ZT 145
2 x (3x 120 + 70)
2X (3X 250)
260
ZR/ZT 160
4 x (3x 95 + 50)
2X (3X 315)
188
ZR/ZT 200
4 x (3x 120 + 70)
2X (3X 400)
184
ZR/ZT 250
4 x (3x 120 + 70)
2X (3X 400)
184
ZR/ZT 275
4 x (3x 150 + 95)
2X (3X 500)
188
Compressors designed for a maximum ambient temperature of 40 °C (104 °F) with IE3 motors
Type
FLA
MCA
Proposed cable
(mm²)
Maximum
cable
length (m)
Proposed
fuses (A)
(gL/gG)
Maximum
fuse (A)
(gL/gG)
Icc
ZT/ZR 110
228
250
4 X (3 X35+16)
112
2 x(3 X 200) 315
50 kA
ZT/ZR 132
268
295
2 X (3 X95+50)
241
2 x(3 X 200) 315
50 kA
ZT/ZR 145
291
320
2 X (3 X120+70)
258
2 x(3 X 250) 400
50 kA
ZT/ZR 160
353
388
2 X (3 X120+70)
258
2 x(3 X 250) 400
50 kA
ZT/ZR 200
433
477
4 X (3 X 95+50)
187
2 x(3 X 315) 400
50 kA
ZT/ZR 250
531
584
4 X (3 X 120+70)
186
2 x(3 X 400) 500
50 kA
ZT/ZR 275 (7.5
bar)
566
622
4 X (3 X 120+70)
186
2 x(3 X 400) 800
50 kA
ZT/ZR 275 (8.6
and 10 bar)
659
725
4 X (3 X 150+95)
188
2 x(3 X 500) 500
50 kA
Instruction book
2920 1815 04
215
Summary of Contents for ZR 110
Page 2: ......
Page 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Page 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Page 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Page 326: ......
Page 327: ......