Control panel
Control panel of Elektronikon GraphicPlus controller
General
Normally, the compressor runs in automatic operation, i.e. the electronic regulator loads, unloads, stops and
restarts the compressor automatically. LED (7) is then alight.
If required, the compressor can be unloaded manually. In this case, the compressor is switched out of
automatic operation i.e. the compressor remains running unloaded unless it is loaded again manually.
Manual unloading
Starting from the main screen, move the cursor so that Unload is highlighted in grey. When the Enter key is
pressed, the compressor starts running unloaded and LED (7) fades. The message
Manual Unload
appears
on the display.
Manual loading
Starting from the main screen, move the cursor so that Load is highlighted in grey. When the Enter key is
pressed, LED (7) lights up and the compressor starts running loaded in case the air net pressure drops
below the programmed level. The message
Load
appears on the display.
If the
Load
or
Unload
buttons are not displayed on the bottom line of the screen, make
sure to return to the Main screen first.
Instruction book
276
2920 1815 04