Regular checks
The following checks should be carried out regularly to ensure safe operation and long service life.
Depending on the environmental and working conditions of the compressor, the local Atlas Copco Service
center may overrule the standard maintenance schedule; always check if in doubt.
Please keep following checks in mind:
• Keep the dryer clean. (if applicable)
• Regularly brush and blow off the finned surface of the air cooler(s) (if applicable)
• Regularly test the water drains
Period
Running hours
Operation
--
At initial start
Check the dryer adjustment as specified in
Initial start-up
.
Daily
8
Check the Elektronikon display for warnings.
Daily
8
Check that condensate is discharged from the drain receivers
during loading.
Daily
--
Before stopping:
• Drain the aftercooler drain receiver
• Drain the intercooler drain receiver
• On Full-Feature compressors, drain the drain receivers of
the internal dryer, and additional aftercooler for energy
recovery units.
Weekly
--
Check the oil level. Refer to
Before starting
.
Weekly
--
Drain condensate from the air receiver, if installed.
Weekly
--
Check for leaks. Tighten leaking connections and replace
damaged/leaking parts.
3-monthly
--
Clean compressor.
3-monthly
500
Check coolers, clean if necessary.
2-yearly
16000
Replace the demister sponge of the integrated dryer.
2-yearly
16000
Inspect the dryer heater
2-yearly
16000
Inspect the dryer rotor
When displayed
--
Carry out service actions according to the displayed service
warnings or service plans as shown below.
• When operating in a dusty atmosphere, inspect the air filters more frequently. Always
use Atlas Copco filters to guarantee the performance of your compressor.
• Grease the motor bearings at the correct interval and with the correct grease type and
quantity as mentioned on the motor data plate. If in doubt, consult your Atlas Copco
Service center.
Service plan
A number of service operations are grouped (called level A, level B, level C, ...). Each level stands for a
number of service actions to be carried out at the time intervals programmed in the Elektronikon regulator.
When a level is reached, a message will appear on the screen. After carrying out all service actions, reset
the interval timers using the "Reset" key in the "Service" menu.
Instruction book
2920 1815 04
283
Summary of Contents for ZR 110
Page 2: ......
Page 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Page 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Page 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Page 326: ......
Page 327: ......