Temperature correction factors
Medium temperature
(°C)
Medium temperature
(°F)
Correction factor for maximum working pressure of
the compensator
0
32
1
50
122
1
80
176
1
85
185
0.92
90
194
0.83
95
203
0.75
100
212
0.67
105
221
0.6
110
230
0.54
Torque values
Compensator bolts should be torqued in 3 successive steps
• Step 1: Hand-tighten each bolt.
• Step 2: Torque the bolts crosswise up to the value mentioned in the table below and allow a
stabilization period of 30 minutes before moving to step 3.
• Step 3: Torque the bolts crosswise up to the value mentioned in the table below.
• Mind the parallelism of the sealing.
• Excessive torque will damage the sealing.
DN
(mm)
DN
(inch)
Step 1
Step 2
(Nm)
Step 2
(lbfin)
Step 3
(Nm)
Step 3
(lbfin)
20 – 80
2 – 3
hand tight
50
443
80
708
100 – 300
4 – 12
hand tight
50
443
100
885
350 – 500
14 – 20
hand tight
50
443
130
1551
Do's and don'ts
The supplied compensators are NOT designed:
• to carry the weight of the mounted customer pipe end.
• to work as a damper for unanchored pipe ends.
• to carry the thrust forces of the compressed air.
Therefore, adequate supporting and anchoring of the customer pipe end should be foreseen to avoid
compensator damage.
Instruction book
2920 1815 04
209
Summary of Contents for ZR 110
Page 2: ......
Page 179: ...Dimension drawing of ZT 110 up to ZT 145 page 1 Instruction book 2920 1815 04 177 ...
Page 214: ... CORRECT installation Instruction book 212 2920 1815 04 ...
Page 249: ...Electric cabinet of compressor with starter Model year 2014 Instruction book 2920 1815 04 247 ...
Page 326: ......
Page 327: ......