Stopping
Control panel
Control panel of Elektronikon controller
Procedure
Frequently stopping the compressor using the emergency stop button may damage the
compressor. Only use the emergency stop button in case of emergency.
Step
Action
1
Close the air outlet valve.
2
Press stop button (9). The compressor will run unloaded for 3 seconds and then stop.
3
To stop the compressor in case of emergency, press the emergency stop button (S2).
Alarm LED (7) starts flashing. After remedying the trouble, unlock the emergency stop
button by pulling it out.