![Atlas Copco ZR 110 Instruction Book Download Page 290](http://html.mh-extra.com/html/atlas-copco/zr-110/zr-110_instruction-book_3001728290.webp)
Oil system components, ZT 110 up to ZT 275
Procedure
Step
Action
1
Run the compressor until warm.
2
Stop the compressor.
Press the emergency stop button.
3
Switch off the voltage and follow the LOTO procedure. (Refer to the
Safety Precautions
before acting.)
4
The filler plug and drain points are painted yellow.
Remove filler plug (FC). Drain the compressor sump by opening drain valve (Dmo).
On ZR compressors, drain the oil cooler by opening drain valve (Dmc).
On ZT compressors, fit a proper flexible over the extension of drain plugs (Dmc). Drain
the oil system by loosening the drain plugs.
Close the drain valves and tighten the drain plugs after draining.
5
Remove the oil filters (OF). Clean the filter seats, oil the gaskets of the new filters and
screw the filters into place until the gaskets contact the seats. Then tighten by hand.
6
On ZR 110 up to ZR 275, fill the compressor sump to the middle of the oil level sight-
glass (SG).
On ZT 110 up to ZT 275, fill the compressor sump to the maximum mark of the oil level
sight-glass.
See
7
Reinstall the filler plug.
Instruction book