Level 2 Maintenance Training, Century Series
2-5
P/N 73-0028-00 Revision A
Level 2 Module 2
STUDENT GUIDE
LESSON 4
Dispenser I/O
OBJECTIVE:
Upon completion of this lesson, the student should be able to list
and test the dispenser I/O.
Listing the Dispenser I/O
ASYMTEK I/O MAP, CENTURY SERIES
IN#
FUNCTION
OUT#
FUNCTION
DA0
DA0
Valve 1 Reverse/Rotate
DA1
DA1
Valve 1 Forward/Jet 1 Trigger
DA2
Tactile Sensor
DA2
Valve 2 Reverse/Rotate
DA3
Low Fluid Sensor
DA3
Valve 2 Forward/Jet 2 Trigger
DA4
Needle Sensor
DA4
Dual Action
DA5
DA5
Purge Cup
DA6
Recoverable Interlock
DA6
Valve 1 Air
DA7
Height Sensor
DA7
Valve 2 Air
DB0
Low Pressure Sensor
DB0
Red Light Steady
DB1
DB1
Yellow Light Steady
DB2
Valve Fault
DB2
Blue Light Steady
DB3
DB3
Red Light Flashing
DB4
DP2000-1 Busy
DB4
Yellow Light Flashing
DB5
DP2000-2 Busy
DB5
Blue Light Flashing
DB6
DP2000-1 Chamber Low
DB6
Audible Alarm
DB7
DP2000-2 Chamber Low
DB7
(Spare)
DC0
External Input-1
DC0
DP2000-1 Prime
DC1
External Input-2
DC1
DC2
External Input-3
DC2
DP2000-1 Home
DC3
External Error
DC3
DC4
Chamber Error
DC4
Valve Reset
DC5
DC5
DC6
DC6
DC7
DC7
B5
AUX1 U
B3
AUX Index Request
B6
B4
AUX U
TS-03 Test Box I/O Testing
Ports under the I/O board can access the Dispenser I/O.
Summary of Contents for C702
Page 6: ...Level 2 Maintenance Training Century Series iv P N 73 0028 00 Revision A ...
Page 10: ...Level 2 Maintenance Training Century Series iv P N 73 0028 00 Revision A ...
Page 26: ...Level 2 Maintenance Training Century Series 1 16 P N 73 0028 00 Revision A ...
Page 50: ...Level 2 Maintenance Training Century Series 2 24 P N 73 0028 00 Revision A ...
Page 66: ...Level 2 Maintenance Training Century Series 3 16 P N 73 0028 00 Revision A ...
Page 78: ...Level 2 Maintenance Training Century Series 4 12 P N 73 0028 00 Revision A ...
Page 80: ...Level 2 Maintenance Training Century Series APPENDIX P N 73 0028 00 Revision A ...
Page 82: ...Level 2 Maintenance Training Century Series APPENDIX P N 73 0028 00 Revision A ...