Level 2 Maintenance Training, Century Series
3-11
P/N 73-0028-00 Revision A
Level 2 Module 3
STUDENT GUIDE
LESSON 3
The Dispensing Valve, CONTINUED
DP2424 CLEANING MAINTENANCE
Routine Use
Once a month.
Fluid Type Change
Before using a new fluid.
Curable Materials
Immediately after use.
Clogged Needle Tip
Immediately.
Poor Dispensing
Prime the pump.
Every 60.000 Cycles
Replace the stopcock insert.
TOOLS AND
MATERIALS
NEEDED
•
3/21-inch hex key
•
5/64-inch hex key
•
Bottle Brush
•
5/8-inch wrench
•
Solvent (compatible with your fluid)
•
Seal Removal tool
•
Crescent Wrench
•
Soft Cloth
•
Mild solvent