CHALLENGE requires the user send their username/password and then they are prompted with a short challenge
code. This S530 does not support this option.
SEND PASSWORD will generate a single-use password and send it to the Email address(es) specified by the
Send Password To option. That password will only allow a login for the user whom it was generated for.
CALLBACK (via Modem) will cause the S530 to do an immediate callback to the Secure Callback number(s)
configured further down in this menu.
For Telnet / Modem, Send Password To
sets the Email address(es) where the single-use password is to be sent.
Secure Authentication via Local Command Port
toggles between OFF (regular), and CHALLENGE. Because the
user is connected via the local Console port, Send Password is not an option. Default setting is OFF.
Password Expires After
sets the number of minutes (0 – 180) before the single-use password expires. A setting of 0
means the password will never automatically expire. Default setting is 0.
Secure Callback n
sets the modem callback numbers. If configured, the S530 will disconnect any modem
connections from this user and then attempt to dial out to each of these numbers. If one of the numbers answers, the
other end must respond with the login credentials of the user used to initiate the callback. (Max length 48 chars)
Authentication Settings
SiteBoss 530 - Authentication Settings
A) Local Command Requires Password [OFF]
B) Modem Callin Requires Password [OFF]
C) TCP/IP Port 23 Requires Password [ON]
D) TCP/IP Port 210x Requires Password [OFF]
E) TCP/IP Port 220x Requires Password [OFF]
F) Username and/or Password Required [PASSWORD ONLY]
Authentication Settings set parameters for passwords and security that are required for
every
user who attempts to
log into the S530.
Local Command Requires Password
is an ON/OFF toggle to set whether a password for I/O2 users is required.
Default setting is OFF.
Modem Callin Requires Password
is an ON/OFF toggle to set whether a password for modem users is required.
Default setting is OFF.
TCP/IP Port 23 Requires Password
is an ON/OFF toggle to set whether a password for Telnet (port 23) users is
required. Default setting is ON.
TCP/IP Port 210x Requires Password
is an ON/OFF toggle to set whether a password for passthrough (port 210x)
users is required. Default setting is OFF.
TCP/IP Port 220x Requires Password
is an ON/OFF toggle to set whether a password for Real-Time Socket (port
220x) users is required. Default setting is OFF.
Note:
When any of the above options is set to OFF, users connecting via that method are automatically granted
Master access.
Username and/or Password Required
toggles between: PASSWORD ONLY, USERNAME/PASSWORD (PW), or
PASSWORD(PW)/USERNAME. Default setting is PASSWORD ONLY.