A.14.16. Communication
TITAN-SVX supports TITAN-ASCII and MODBUS protocols.
Changing the protocol from TITAN-ASCII to MODBUS can be done easily but
changing the protocol from MODBUS to TITAN-ASCII can only be done using the
Special Request commands.
TITAN Windows UI program can be used to change the protocol easily. If using
a terminal program, Special Request Commands can be manually typed to
change the protocol.
TXDELAY
command is used to set the transmission delay time before the reply
is sent from TITAN-SVX to give some time for the master to release the RS485
line. Each
TXDELAY
unit is 0.25msec.
TXDELAY
value of 10 means 2.5msec.
Default
TXDELAY
value is 0.
Inquire about the transmission delay value
Command:
@01:TXDELAY
Reply:
#01:TXDELAY=0
Change the transmission delay time
Command:
@01:TXDELAY=20
Reply:
#01:TXDELAY=20