TITAN-SVX Software Manual
page 13
Rev 4.01
Example 3:
Command from Master to TITAN-SVX
@01:EX;VX*868C[CR][LF]
Reply from TITAN-SVX to Master
#01:EX=830141;VX=0*4D60[CR][LF]
Multiple commands are sent on a single string along with the CRC
Checksum characters. The reply comes back with the CRC characters.
3.4. Communication Mode 3
Communication Mode 3 is exactly same as the Communication Mode 2 with the
exception that only the valid commands are replied. RS-485, USB, and Ethernet
communication are capable of utilizing communication mode 3.
For example, sending wrong CRC value characters will not result in a reply.
Wrong commands also will not result in a reply.
Example 1:
Command from Master to TITAN-SVX
@01:EX*1234[CR][LF]
No reply from TITAN-SVX will be sent since the CRC check characters
are invalid.
NOTE:
Only the valid commands will be replied in Communication Mode 3.