A.10. Fault Monitoring Commands
Command
RW
Description
CEMS
RW
Current Error Duration in Milliseconds
CEVAL
RW
Current Error Value in milliamps
ENAFC
RW
Enable Position and Current Fault Monitoring
Bit 0 – Enable Position Error Monitoring
Bit 1 – Enable Current Error Monitoring
ESTOP
RW
Digital Input 5 configured as an emergency input.
When this input is triggered, the motor is disabled and fault flag is set.
Value 0 – disable emergency input
Value 1 – Enable emergency active high
Value 2 – Enable emergency active low
OCUR
RW
Peak Motor Current Monitoring Value. The default value of
8A
is always
set at power up. Peak current monitoring is always enabled for the
protection of the motor and driver.
OCUR
value can be changed to a
lower current threshold value.
OCCUR
cannot be raised above
8A
.
OVOL
RW
Peak Power Supply Voltage Monitoring Value. The default value of
65V
is always set at power up. Peak voltage monitoring is always enabled
for the protection of the motor and driver.
OVOL
value can be changed
to set to a lower voltage threshold value.
OVOL
cannot be raised above
65V
.
PEMS
RW
Position Error duration Milliseconds
PEVAL
RW
Position Error Value in encoder counts
UHEA
RW
Overheat Temperature Monitoring Value. The default value of
80 deg C
is always set at power up. Temperature monitoring is always enabled for
the protection of the motor and driver.
UHEA
can be lowered but not be
raised higher than 80.
UVOL
RW
Under Power Supply Voltage Monitoring Value. The default value of
10V
is always set at power up. Under-voltage monitoring is always enabled
for the protection of the motor and driver.
UVOL
value can be changed
to set to a higher voltage threshold value.
UVOL
cannot be lower than
10V
or raised above
65V
.
Table A.9
A.11. Miscellaneous Commands
Command
RW
Description
FIRMVS
R
Returns Firmware Version
MOTNAME
RW
Returns Motor Product Name
NETID
RW
Returns and sets RS485 Network ID. The range is 1 to 99. Once
Network ID is set, it must be stored to flash and controller reboot for the
new ID to take effect.
PWRC
R
Power source current usage
PWRV
R
Power source voltage
RESET
W
Resets the controller.
STORE
W
Stores all parameters to flash memory. Once the store command is
issued, wait at least 500msec before communication started.
TEMP
R
FET temperature
SYSTIME
RW
Returns number of seconds since the last power up.
RUNTIME
RW
Returns number of seconds motor is enabled and moving (velocity non-
zero). Value is reset at zero at power up.
Table A.10