TITAN-SVX Software Manual
page 25
Rev 4.01
Appendix A. TITAN-ASCII Commands
Notes:
1. All TITAN-ASCII commands (Communication Mode 0, 1, 2, and 3) must
start with the start character @, two Network ID characters, and a
semicolon character and ending CR and LF characters.
2. All valid commands are replied with the start character #, two Network ID
characters, and a semicolon characters with ending CR and LF
characters.
3. Invalid commands are replied with an error message in Communication
Mode 0 and 2 only.
4. After the command is sent, Master must release the RS-485 line
immediately and wait for the complete reply message before to avoid any
collision in the message. Sending characters or message while the reply
is being sent or RS-485 line not being released when the reply message is
sent will result in an unrecognizable garbled message.
5. Commands can be Read-Only, Write-Only, or Read/Write denoted by R,
W, RW.
6. All valid commands are replied with a message!
7. Invalid commands may or may not be replied depending on the
communication mode.
NOTE:
Besides the published TITAN-ASCII commands listed in this
document, additional non-published commands exist. Users of
TITAN-SVX are highly recommended to use only the published
commands. Using wrong commands may result in an unexpected
situation which may result in the damage of the products and a
potentially dangerous situation for the user.