"FENCE NOZZLE" function enabled
This function entails the assembly of specific nozzles at boom end; these nozzles allow spraying areas that cannot be reached by the traditional
nozzles due to the boom size (i.e. fences). The enabling of such nozzles does not stop the output from the other boom nozzles.
The connection and pairing procedure of seletron devices and "Fence" nozzles is the following: at first connect all boom nozzles, then the left "Fence"
nozzle and the right "Fence" nozzle.
By setting the reference flowrate and pressure for the "Fence" nozzle, it is possible to control the output of all nozzles based on the set spray rate.
The width covered by the fence nozzle is not included in the calculation of the applied area.
Fig. 136
Fence zone
By activating the function in the basic settings of the implement (chap.
10) it is possible to select normal or special nozzles: the activation of the
"Fence" nozzles does not interrupt the delivery of the other boom nozzles.
Nozzle selection modes are variable (they vary based on the Auxiliary
Input connected to the VT). Following are some examples.
END NOZZLES:
CORRESPONDING ICON ON "HOME" SCREEN
Special LEFT
nozzle
ENABLED
Special RIGHT
nozzle
ENABLED
Special LEFT
nozzle
DISABLED
Special RIGHT
nozzle
DISABLED
EXAMPLE OF NOZZLE SELECTION THROUGH THE SWITCH BOX
• LH special nozzle enabling (Boom view from back)
Press switch to the left once to
enable the LH "Fence" nozzle. The
LED on the left flashes alternately.
• RH special nozzle enabling (Boom view from back)
Press switch to the right once to
enable the RH "Fence" nozzle. The
LED on the right flashes alternately.
• LH special nozzle disabling (Boom view from back)
Press switch to the right once to
disable the LH "Fence" nozzle. The
LED on the left no longer flashes and
is steady.
• RH special nozzle disabling (Boom view from back)
Press switch to the left once to
disable the RH "Fence" nozzle. The
LED on the right no longer flashes
and is steady.
EXAMPLE OF NOZZLE SELECTION THROUGH THE JOYSTICK
Seq. 1 RH
Seq. 2 LH
Seq. 1 LH
Seq. 2 RH
The operation is similar to the one just described for the sequential switch box.
The functions associated to nozzle enabling are included in the "Main" page.