23
IMPLEMENT SETTINGS
11.4
Home > data and settings > implement settings > Valves
It allows configuring the main valve, the pressure control valve and the section valves:
1
2
3
4
Fig. 44
5
6
Fig. 45
1
Main Valve > Type
Main control valve installed. Available options are:
None
,
2 ways
(drain valve),
3 ways
(main valve).
The item
Main Valve > Type
is shown as a REMINDER: it is activated during the guided setup (
It can not therefore be modified on this screen.
2
Main Valve > Auto closing of section valves
Allows to enable/disable the section automatic closing when the main control valve is closed.
On a Seletron system, auto closing of section valves is active by default (
“M” type
).
•
"M" operating mode
( option
):
the section valves are closed or opened by operating the main control valve based on the settings of the controls relating to the single section valves,
namely:
- if section controls are set to OFF, when main control is operated, the sections will stay closed;
- if the control of one or more section valves is set to ON, when main valve is closed or opened, the section valves will be closed or opened as well.
ENABLED MODE CAN NOT BE MODIFIED:
this condition occurs when no main valve is installed on the system or the installed one is a
2-way
valve.
•
"P" operating mode
(option
):
The section valves are controlled independently.
Main valve control functions do not affect section valve opening or closing.
3
Main Valve > auto closing of main valve
When all section valves are closed and this option is enabled, the main valve is automatically closed as well.
(
Main valve automatic closure enabled /
Main valve automatic closure disabled).
ENABLED MODE CAN NOT BE MODIFIED:
this condition occurs when no main valve is installed on the system
.
4
Pressure regulating valve > Reverse direction
Indicate the type of installed control valve. Available options are:
Reverse direction enabled =
Reverse direction disabled =
5
Section valves > Type
Indicate the type of installed section valves. Available options are:
•
2 ways
(valves without metered by-pass)
•
3 ways
(valves with metered by-passes)
On a Seletron system, section valves are of the
2 ways
type (without metered by-passes) and are automatically set.
6
Section valves > Nominal current
FOR SELETRON SYSTEMS, ONLY
Enter the maximum operating current value for each section valve.
Quits without confirming the
changes
Saves the changes
Cancel
Exits
Confirm
Goes back to previous menu,
or scrolls the pages of a menu
(previous page)
Scrolls the pages of a menu
(next page)
Goes back to main screen
Saves the changes to current
page
Summary of Contents for 4679004