28
IMPLEMENT SETTINGS
11.9.3
Home > data and settings > implement settings > Device calibration > Tank profile calibration
The calibration of the tank profile is ONLY possible if a flowmeter is installed on the system.
Before starting the procedure carry out the following operations:
1
Make sure the main control is in OFF position
2
Fill the tank with clean water WITHOUT ADDING CHEMICAL SUBSTANCES. The tank must be full.
Visually check the reached level.
3
Set the output to the maximum value by operating the control valve switch (nearly 7 s).
THE FLOWRATE MUST BE WITHIN THE FLOWMETER OPERATING RANGE.
4
Start the procedure by pressing
Start
.
5
Start the spraying system: open, in succession, all section valves and the main control (
ON
).
The display will show in real time the quantity of sprayed water and the calibration status.
6
When the tank is empty press
Confirm
to end the procedure:
the value read by the level sensor must be lower than 5.0 mA and at least 10 liters must have been sprayed.
4
Fig. 54
5
6
Fig. 55
In the HOME page, this icon is displayed on the tank when a calibration curve is associated with it.