70
17.4
Troubleshooting
PROBLEM
CAUSE
SOLUTION
Section valve controls take no effect
Valves not connected
• Connect the IN-CAB cable and the connection cable to the valves.
One valve does not open
No power supply to valve
• Check valve electric connection and operation.
The display no longer shows the speed
Wrong setup
• Check the setup of the wheel constant.
No signal coming from the speed sensor
• Check connections to speed sensor.
The displayed speed is not precise
Wrong setup
• Check the setup of the wheel constant.
Output volume readout inaccurate
Wrong setup
• Check the setup of the boom width.
• Check the setup of the flowmeter constant.
• Check the setup of the wheel constant.
• Check the setup of the section valve type.
• Check connections to speed sensor.
Covered area count displayed does not
match actual area covered
Wrong setup
• Check the setup of the boom width.
• Check the setup of the wheel constant.
• Check connections to speed sensor.
Counter not reset
• Reset the counter.
Traveled distance count displayed does not
match actual distance covered
Wrong setup
• Check the setup of the wheel constant.
• Check connections to speed sensor.
Counter not reset
• Reset the counter.
Sprayed fluid count displayed does not
match liters/gpm actually sprayed
Wrong setup
• Check the setup of the flowmeter constant.
• Check the setup of the section valve type.
Counter not reset
• Reset the counter.
Use of three-way section valves without setting
metered by-passes
• Perform setting.
Time count displayed does not match actual
work time
Counter not reset
• Reset the counter.
Unable to reach output volume value set for
the automatic operation
Wrong setup
• Check spray rate setup.
• Check the setup of the boom width.
System not adequately sized to provide required
flowrate
• Check maximum pressure valve adjustment.
• Make sure control valve is adequate for specific system.
Control valve malfunction
• Check valve operation.
Instantaneous pressure readout inaccurate
Wrong setup
• Check full scale setup for pressure sensor.
Pressure sensor not calibrated
• Perform setting.
Pressure sensor wrong installation
• Check connections to pressure sensor.
Instantaneous pressure is not displayed
Wrong setup
• Check pressure sensor setting.
IBX100 does not receive signals from pressure
sensor
• Check connections to pressure sensor.
Pressure sensor wrong installation
• Check connections to pressure sensor.
Rpm readout inaccurate
Wrong setup
• Check rpm sensor constant setting.
Rpm value not displayed
IBX100 does not receive signals from RPM sensor
• Check connections to RPM sensor.
Rpm sensor wrong installation
• Check connections to RPM sensor.