73
TECHNICAL DATA
SELETRON sprayer technology
Fig. 140
A
SENSOR CABLE
PIN
IBX100 signal
A1
12V sensor power supply
A2
Pressure sensor (M)
A3
Level sensor (L)
A4
-
A5
-
A6
-
A7
-
A8
GND sensor power supply
B1
Proportional valve
B2
Spraying activation / deactivation
B3
-
B4
-
B5
-
B6
-
B7
-
B8
G 12V valve power supply
C1
Proportional valve
C2
Speed sensor (S)
C3
Flowmeter (F)
C4
Filling flowmeter (T)
C5
RPM sensor (X)
C6
Flashing light (Z)
C7
Boom lighting (Z)
C8
G GND valve power supply
B
SELETRON
Line 2
PIN
IBX100 signal
A1
GND
A2
-
A3
-
A4
-
A5
-
A6
-
A7
-
A8
VBAS
B1
GND
B2
-
B3
CAN L
B4
CAN H
B5
-
B6
-
B7
-
B8
VBAS
C1
GND
C2
-
C3
-
C4
-
C5
-
C6
-
C7
-
C8
VBAS
C
SELETRON
Line 1
PIN
IBX100 signal
A1
GND
A2
-
A3
-
A4
-
A5
-
A6
-
A7
-
A8
VBAS
B1
GND
B2
-
B3
CAN L
B4
CAN H
B5
-
B6
-
B7
-
B8
VBAS
C1
GND
C2
-
C3
-
C4
-
C5
-
C6
-
C7
-
C8
VBAS
D
ISOBUS CABLE
Tractor / Self-propelled
PIN
IBX100 signal
A1
PWR
A2
-
A3
-
A4
-
A5
-
A6
-
A7
PWR
A8
PWR
B1
PWR GND
B2
-
B3
CAN L
B4
CAN H
B5
-
B6
-
B7
ECU-POWER
B8
PWR
C1
PWR GND
C2
PWR GND
C3
-
C4
-
C5
TBC-POWER
C6
TBC GND
C7
ECU-POWER GND
C8
PWR GND
Summary of Contents for 4679004