Using the Script Menu
MT8850A / MT8852A Bluetooth Test Set
13000-000109
8-51
January 2003
Viewing Test Results
Maximum Input Power Test Results
Standard mode
1.
Choose “Max input power” from the Script menu.
2. Press
the
[Results]
soft key.
The Maximum input power results screen is displayed.
3. Press
the
[1 of 3]
soft key to move to the second screen.
4. Press
the
[2 of 3]
soft key to move to the third screen.
Definition of test results
Current BER
Displays the BER as measured in the last 10 returned packets.
Overall BER
Displays the BER for all the returned packets.
Current FER
Displays the FER as measured in the last 10 returned packets.
Overall FER
Displays the FER for all the returned packets.
FER due to
CRC
Displays the number of packets returned that had a CRC error. These
packets are used in BER calculations.