A – Movement feed rate determines printing speed (100% by default, can be varied within a range of 25 to 200%).
B – Plastic flow parameters adjust extrusion coefficients of plastic in a percentage manner. Plastic flow range is
from 25 to 150%).
C – Temperature correction value increases or decreases predefined temperature on set increment (0 °C by
default, can be varied within a range of -100 to 100 °C). Note that the temperature is limited by 270 °C for
extruders and 120 °C for buildplate.
D – Fan correction value increases or decreases predefined fan power (0 % by default, can be varied within a
range of -100 to 100%).
4 – Axis positioning (see MAIN SCREEN)
5 – Loading/unloading materials (see LOADING MATERIALS)
6 – Debug info is service information (for service engineer if required)