C13143
000.
fm
- 13 -
IT
GB
DE
FR
ES
English
A variety of optional installation kits
are available for arranging applian-
ces in banks:
D)
"Over cupboard" installation kit.
E)
Supporting frame kit
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The appli-
ance is supplied with operating voltage
400V/3N, which can be switched to 230V/3
(see next point).
Caution - warning
Before doing any work, cut off the mains
electricity supply.
ELECTRICAL CONNECTION
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A)
with overload cutout and differential safety
breaker close to the appliance.
2 - Remove the control panel
(B)
.
3 - Connect the circuit-breaker
(A)
to the terminal
board
(C)
of the appliance as shown in the dia-
gram and in the electrical system diagram at the
back of the manual.
N.B.: use a cable with at least H05RN-F cha-
racteristics.
Important
When connecting, take care to connect the
neutral and earth lines.
4 - Replace
the control panel (
B
) on completion of
the operation.
A
B
IDM-39604002300.tif
C
D
E
C13143000.fm Page 13 Thursday, June 12, 2008 2:23 PM
Summary of Contents for 0G0FR3E
Page 2: ...C13143000 fm Page 0 Thursday June 12 2008 2 18 PM ...
Page 18: ...C13143000 fm Page 0 Thursday June 12 2008 2 23 PM ...
Page 34: ...C13143000 fm Page 0 Thursday June 12 2008 2 30 PM ...
Page 50: ...C13143000 fm Page 0 Thursday June 12 2008 2 33 PM ...
Page 66: ...C13143000 fm Page 0 Thursday June 12 2008 2 35 PM ...