AD9361 Reference Manual
UG-570
| Page 81 of 128
0x035 = 0x1E (GAIN CONTROL, TEMP SENSE
VALID, AUXADC VALID)
Control Output 7 (CH1 Low Thresh Exceeded)
This signal only applies to the slow AGC. If the signal power
drops below the inner low threshold, this signal goes high until
the measured power is no longer lower than the threshold.
When this condition occurs, the slow AGC will adjust the gain
in an attempt to keep the signal power between the two inner
thresholds. After the gain changes (and assuming that the signal
power is now within the inner thresholds), this signal will
remain high until a new power measurement completes. Thus,
it can be hundreds of microseconds or longer before this signal
transitions low, even though the gain change has already
occurred.
Control Output 6 (CH1 High Thresh Exceeded)
Similar to Control Output 7 but applies to the inner high
threshold of the slow AGC.
Control Output 5 (CH1 Gain Upd Count Exp)
This signal pulses high when the slow AGC gain update counter
expires. The length of the pulse depends on the
AD9361
internal clock rates. For the standard LTE 10 MHz customer
software profile, the signal is high for approximately 40 ns.
Control Output 4 and Control Output 3 (CH1 AGC
State[1:0])
See 0x035 = 0x0F Control Output 7 and Control Output 6.
Control Output 2 (CH1 Gain Change)
See 0x035 = 0x08 Control Output 4.
Control Output 1 (Temp Sense Valid)
This signal changes state when the temperature sensor word is
valid. The BBP can manually start a temperature measurement
or it can set up the
AD9361
for periodic measurements. For
periodic measurements, this control output signal will be a
square wave with a period equal to double the measurement
time interval.
Control Output 0 (AuxADC Valid)
If the AuxADC is enabled, this signal changes state when the
AuxADC word in Register 0x01E and Register 0x01F is valid.
This signal will be a square wave with a period equal to twice
the update time of the AuxADC.
0x035 = 0x1F (GAIN CONTROL)
Control Output 7 (CH2 Low Thresh Exceeded)
Same as 0x035 = 0x1E Control Output 7 but applies to Rx2.
Control Output 6 (CH2 High Thresh Exceeded)
Same as 0x035 = 0x1E Control Output 6 but applies to Rx2.
Control Output 5 (CH2 Gain Upd Count Exp)
Same as 0x035 = 0x1E Control Output 5 but applies to Rx2.
Control Output 4 and Control Output 3 (CH2 AGC
SM[1:0])
See 0x035 = 0x10 Control Output 7 and Control Output 6.
Control Output 2 (CH2 Gain Change)
See 0x035 = 0x08 Control Output 0.