Appendix B: Wireless Technology
180
MVP-9000i 9" Modero® ViewPoint® Touch Panel with Intercom
Configuring Modero Firmware via the USB Port
The MVP-9000i needs to be configured to connect with a PC to transfer firmware via the mini-USB port. To configure
the touch panel:
Step 1: Configure The Panel For a USB Connection Type
1.
After the panel powers up, hold the
Reset
button to display the
Setup
page (for more information, refer to the
Accessing the Setup pages
section on page 43) and open the
Protected Setup
page.
2.
Press
System Settings
to open the
System Settings
page.
3.
Toggle the blue
Type
field in the
Master Connection
section until the choice cycles to
USB
.
4.
Press the
Back
button on the touch panel to return to the
Protected Setup
page.
5.
Press the
Reboot
button both to save any changes and to
restart the panel.
Remember that the panel’s connection
type must be set to
USB
prior to rebooting the panel and prior to inserting the USB connector.
6.
ONLY AFTER
the unit displays the first panel page should you
THEN
insert the mini-USB connector into the
Mini-USB Port on the panel. It may take a minute for the panel to detect the new connection and send a signal to the
PC,
indicated by a green System Connection icon
.
If a few minutes have gone by and the
System Connection
icon still does not turn green, complete the
procedures in the following section to set up the Virtual Master and refresh the System from the Online Tree.
This action sends out a request to the panel to respond and completes the communication, turning the
System
Connection
icon green.
7.
Repeat steps 2 and 3 to return to the
System Settings
page
Step 2: Prepare NetLinx Studio For Communication Via the USB Port
1.
From the
Start
menu in Windows XP, open the
Network Connections
dialog (
Start
>
Settings
>
Network
Connections
>
Local Area Connection
).
2.
Look for the Local Area Connection reading
Local Area Connection, AMX USB Device Link
and double-click on it
to open the Local Status.
3.
Press the
Properties
tab to open the
Local Area Connection Properties
section.
4.
Press the
Properties
button to open the
TCP/IP Properties
dialog box.
5.
Set the IP address to an address within the same subnet as the panel IP address specified within the USB IP settings
of the panel. For instance, if the default IP address on the device is
172.16.0.2
, set the IP address to
172.16.0.1
. Use
any class and number currently not being used by your network.
6.
Set the Subnet Mask to
255.255.0.0
.
7.
In the
TCP/IP Properties
dialog box, click
OK
.
8.
In the
Local Area Connection Properties
, section, click
Close
.
ALL
fields are then greyed out and read-only. However, they still display any previous
network information.
Summary of Contents for MVP-9000i
Page 14: ...10 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 38: ...Accessories 24 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 56: ...Configuring Communication 42 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 72: ...Setup Pages 58 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 200: ...Appendix C Troubleshooting 186 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 201: ...Appendix C Troubleshooting 187 Enter the Document Name Here ...