Configuring Communication
37
MVP-9000i 9" Modero® ViewPoint® Touch Panel with Intercom
Ethernet
1.
When using Wireless Ethernet, press the listed
Mode
in the
Master
tab to toggle through the available connection
modes:
2.
Select the
Master Port Num. field
to open the keypad and change this value.
The default setting for the port is
1319
.
3.
Set the Master Port and select
OK
.
4.
If you enabled password security on your Master, set the username and password within the device.
5.
Select the blank field
Username
to open the keyboard.
6.
Set the Username and select
OK
.
7.
Select the blank field
Password
to open the keyboard.
8.
Set the Password and select
OK
.
9.
Press the
Back
button twice to return to the
Status
page.
Master Connection to a Virtual Master via Ethernet
Before beginning:
1.
Verify that the panel has been configured to communicate with the Wireless Access Point and confirm that the
signal strength quality bargraph is
On
.
2.
In NetLinx Studio, select
Settings
>
Master Communication Settings
from the
Main
menu to open the
Master
Communication Settings
dialog (FIG. 40).
3.
Click the
Communications Settings
button to open the
Communications Settings
dialog (FIG. 41).
4.
Click on the
Virtual NetLinx Master
radio button (
from the Platform Selection section
) to indicate that you are
working as a NetLinx Master.
Connection Modes
Mode Description
Procedures
None
No connection
None
Auto
The device connects to the first master that
responds. This setting requires setting the
System Number.
Setting the System Number:
1. Select the
System Number
to open the keypad.
2. Set your System Number and select
Done
.
URL
The device connects to the specific IP of a
Master via a TCP connection. This setting
requires setting the Master’s IP.
Setting the Master IP:
1. Select the
Master IP
number to the keyboard.
2. Set the Master IP and select
Done
.
Listen
The device "listens" for the Master to initiate
contact. This setting requires providing the
Master with the device’s IP.
Confirm that the device IP is on the Master URL
list. Set the Host Name on the device and use it to
locate the device on the Master. Host Name is
particularly useful in the DHCP scenario, where
the IP address can change.
When configuring the panel to communicate with a Virtual Master on your PC via
wireless Ethernet, the Master IP/URL field must be configured to match the IP
Address of the PC. Make sure to use the Virtual System value assigned to the Virtual
Master within NetLinx Studio.
FIG. 40
Master Communications Settings dialog
Summary of Contents for MVP-9000i
Page 14: ...10 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 38: ...Accessories 24 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 56: ...Configuring Communication 42 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 72: ...Setup Pages 58 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 200: ...Appendix C Troubleshooting 186 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 201: ...Appendix C Troubleshooting 187 Enter the Document Name Here ...