Configuring Communication
39
MVP-9000i 9" Modero® ViewPoint® Touch Panel with Intercom
14.
Press the
Mode
field until the choice cycles to the word
URL
.
By selecting
URL
, the
System Number
field becomes read-only (grey) because the panel pulls this value directly
from the communicating target Master, virtual or not. A Virtual Master system value can be set within the active
AMX software applications such as NetLinx Studio, TPD4, or IREdit.
15.
Press the
Master IP/URL
field to open a Keyboard and enter the IP Address of the PC used as the Virtual Master.
16.
Click
OK
to accept the new value and return to the
System Settings
page.
17.
Do not alter the
Master Port Number
value, as this is the default value used by NetLinx.
18.
Press the
Back
button twice to open the
Status
page and save your changes.
Using G4 Web Control to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4-enabled panel via the Web. This feature works
in tandem with the browser-capable NetLinx Security firmware update (
build 300 or higher
). Refer to the
G4 Web
Control Settings Page
section on page 83 for more detailed field information.
1.
From the
Setup
page, press the
Protected
button (located on the lower-left of the panel page) to open the
Protected
Setup
page and display an on-screen keypad.
2.
Press the
G4 WebControl
button to open the
G4 Web Control Settings
page (FIG. 44).
3.
Press the
G4 Web Control
button until it toggles to
On
and turns green.
4.
The
Control Name
field is exactly the same as the
Device Name
field in the
Protected Setup
page.
5.
Press the
Control Password
field to open the
Web Password
keyboard.
6.
From the
Web Password
keyboard, enter a unique alpha-numeric string to be assigned as the G4 Authentication
session password associated with VNC web access of this panel.
7.
Press
OK
to save all changes and return to the
G4 Web Control Settings
page or
Abort
to return to the page without
saving any changes.
8.
Press the
Control Port
field to open the
Web Port Number
keypad.
9.
Within the keypad, enter a unique numeric value to be assigned to the port on which the VNC Web Server is
running. The default value is
5900
. Press
OK
after entering the value.
10.
Press the
Up/Down
arrows in the
Timeout
section to increase or decrease the amount of time the device can remain
idle
with no cursor movements
before the session is closed and the user is disconnected. The options are Off; 3, 5,
10, 15, and 30 minutes; and 1, 2, 3, and 4 hours.
G4 Web Control cannot display page transitions or Dynamo images that are
accelerated in hardware.
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from
www.amx.com
. Refer to the NetLinx Master instruction
manual for more detailed information on the use of the new Web-based NetLinx
Security.
FIG. 44
G4 Web Control Settings page
Summary of Contents for MVP-9000i
Page 14: ...10 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 38: ...Accessories 24 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 56: ...Configuring Communication 42 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 72: ...Setup Pages 58 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 200: ...Appendix C Troubleshooting 186 MVP 9000i 9 Modero ViewPoint Touch Panel with Intercom ...
Page 201: ...Appendix C Troubleshooting 187 Enter the Document Name Here ...