Installation Procedures: 12" and 15" Panels
44
12” and 15” Modero Touch Panels
3.
Remove the magnetic faceplate/bezel (
A
in
FIG. 45) from the main NXD unit (
B
in
FIG. 45) by gripping
the faceplate and pulling with gentle outward force.
4.
Thread the incoming RJ-45, Ethernet, and any other audio/video wiring (from their terminal locations)
through the cutout opening. Refer to the
Wiring Guidelines for the 12" and 15" Panels
section on page 47
for pinout descriptions.
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
5.
Connect all data and power wiring to their corresponding locations along the side of the (un-powered)
NXD touch panel.
Verify the terminal end of the power cable is not connected to power supply before plugging in the
2-pin power connector.
6.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly before finalizing the installation.
7.
Disconnect the terminal end of the power cable from the power supply.
8.
Carefully slide the main unit into the cutout until the Mounting Tabs of the NXD unit lie flush against the
wall.
9.
Insert and secure the four #4 screws into their corresponding holes located along the sides of the NXD
(using a grounded Phillips-head screwdriver) until the unit is secure and flush against the wall.
FIG. 44
NXD 15-inch Wall Mount panel dimensions using #4 mounting screws
FRONT BEZEL
CUTOUT
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the necessary connectors before being inserted into the solid surface.