Installation Procedures: 12" and 15" Panels
37
12” and 15” Modero Touch Panels
Refer to your particular VESA mount manufacturer’s installation procedures for further surface mounting
procedures.
Pre-wall Installation of the Conduit Boxes
Wall Mount panels (NXDs) are contained within a metallic outer housing (back box). This back box is
not
removed
when installing the NXD into a conduit box (CB-TP15 or CB-TP12). The
back box is
only
removed to either gain access for the replacement of the Memory/Compact Flash or upgrade
the unit with an MB-TP Universal VESA Mounting Kit.
The CB-TP12 and CB-TP15 conduit wallboxes are optional metallic boxes that are secured onto stud beams
prior to the installation of a solid surface. Installation procedures and configurations can vary. This section
describes the installation procedures for the most common installation scenario.
1.
Fasten the CB-TP15 or CB-TP12 to a stud through the stud fastening holes, located on the inside of the
conduit box (FIG. 38), by using either nails or screws.
FIG. 37
Installation of grommet into the rear plastic enclosure
Rear plastic cover (rear view)
Rim of the strain relief grommet
should lie flush against enclosure
CLIP FACING UP
VESA mount connection location
(USE ONLY AMX PROVIDED #8-32 screws)
INSTALLER: LEAVE A GAP BETWEEN THE STUD AND CONDUIT BOX TO
ACCOMMODATE THE DRYWALL SHEETROCK.
This gap allows the installation of
the drywall/sheetrock after the conduit box has been installed.