4-2 | Thermox Series 2000 WDG-IV / IVC / IVCM
Control Unit Keys
Each of the Control Unit keys provides a menu of choices.
Key
Function
Setup
Set up the control unit for your specific application.
Calibrate
Set calibration parameters and start calibrations.
Analog Range
Define parameters that control analog current outputs.
Alarm
Define parameters that control the alarm relays.
Help
Access control unit on-line help.
Cancel
Cancels out of menu options.
Enter
Confirm menu choices and values.
Selecting Menu Options
Select a menu option, by pressing the
Down
arrow key until the arrows are
pointing at the menu option, then press
Enter
. The selected choice has an
asterisk (*) in front of it.
For example, if you select the
Display
option from the
Setup
key, and then select
“Display Line 1”, the current choice on display line 1 will have an asterisk in front
of it (for example, % oxygen).
If all menu options are not able to be listed on the display, there will be a
Down
arrow on the far right of the last line of the display. This indicates that
there are more menu options to view. When the
Down
arrow disappears,
there are no more menu options to display. Conversely, if an
Up
arrow ap-
pears on the far right of the first line of the display, there are more menu
options available if you press the
Up
arrow key.
Exiting Menu Options
To exit a menu, press
Cancel
. To exit out of all menus, continue to press
Cancel
until all menus disappear from the display and only process read-
ings remain.
Pressing the Cancel key does not delete any settings you have set
while in that menu.
NOTE
Summary of Contents for Thermox Series 2000 WDG-IV
Page 14: ...xiv Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Page 32: ...2 8 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Page 59: ...Installation 3 27 Figure 3 20 Sensor connections with all sensor options ...
Page 67: ...Installation 3 35 Figure 3 24 Series 2000 2 wire RS 485 communication connections ...
Page 69: ...Installation 3 37 Figure 3 25 Series 2000 4 wire RS 485 communication connections ...
Page 72: ...3 40 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Page 100: ...4 28 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Page 126: ...5 26 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Page 143: ...Service and Parts 7 3 Figure 7 1 Wiring diagram for standard sensor ...
Page 145: ...Service and Parts 7 5 Figure 7 2 Cell replacement ...
Page 155: ...7 15 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Page 181: ...A 26 Thermox Series 2000 WDG IV I VC IVCM This page intentionally left blank ...
Page 185: ...B 4 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Page 191: ...D 2 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...