10.2.15 Checking the top link pin and lower link pin
INTERVAL
daily
1.
Check the top link pins and lower link pins for
cracks or broken areas.
Permissible wear
2 mm
2.
Replace the pins if there is significant wear.
10.2.16 Checking the hydraulic hose lines
INTERVAL
After initial operation
Every 50 operating hours
or
weekly
1.
Check the hydraulic hose lines for damage, such
as chafing point, cuts, tears and deformation.
2.
Check the hydraulic hose lines for leaks.
Hydraulic hose lines must not be more than 6 years
old.
3.
Check the manufacturing date
1
.
CMS-I-00000532
4.
Have any worn, damaged or aged hydraulic
hose lines immediately replaced at a specialist
workshop.
5.
Retighten loose bolted connections.
CMS-T-00002330-H.1
CMS-T-00002331-C.1
10 | Repairing the implement
Maintaining the implement
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE