The TwinTeC coulter is not spreading seed
1.
If the blockage cannot be removed from below,
Remove the hose
4
or
Remove the Y-piece.
2.
Remove the bolt
5
.
3.
Remove the seed outlet
1
.
4.
Clean the seed outlet.
5.
To install the seed outlet,
place the guides
2
in the coulter bodies
3
.
6.
Install the bolt.
7.
Install the hose.
2
3
4
5
1
6 Nm
CMS-I-00003246
The TwinTeC coulter does not guide the seed precisely into the furrow
1.
Remove the hose
6
or
Remove the Y-piece.
2.
Remove the bolt
7
.
3.
Remove the TwinTeC seed outlet
1
.
4.
Remove the bolt
2
.
5.
Replace the guide extension
3
.
6.
Install the bolt.
7.
To install the TwinTeC seed outlet,
place the guides
4
in the coulter bodies
5
.
8.
Install the bolt.
9.
Install the hose.
1
6 Nm
6
7
2
3
1 Nm
4
5
CMS-I-00003242
CMS-T-00006601-B.1
CMS-T-00006594-C.1
8 | Eliminating faults
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE
99