Specifications
104
Goldeye G/CL Technical Manual V4.2.0
Mechanics
Operating conditions
Parameter
Values
Body dimensions (L × W × H)
without lens adapter
78 × 55 × 55 mm
Lens mounts
C-Mount, F-Mount, M42-Mount
Mass, body only, without adapter
330 g
Mass, with C-Mount adapter
350 g
Mass, with F-Mount adapter
400 g
Mass, with M42-Mount adapter
370 g
Table 47: Goldeye CL-034 TEC1 mechanics
Parameter
Values
Operating temperature
-20 °C to +55 °C (case)
Storage temperature
-30 °C to +70 °C (ambient)
Sensor cooling temperature,
setpoints
•
+20 °C (default and calibrated)
•
+5 °C, +35 °C, +50 °C (other setpoints) or user-configurable
Relative humidity
10% to 95%, non-condensing
Power requirements (DC)
10.8 V to 30.0 V
Max. power consumption
11.8 W (12 VDC)
Typical power consumption
without cooling
6.3 W (12 VDC)
Table 48: Goldeye CL-034 TEC1 operating conditions