Specifications
69
Goldeye G/CL Technical Manual V4.2.0
Examples
•
Goldeye G-032 models are available with single-stage temperature control,
and with dual-stage temperature control in a Cool housing. They are named
Goldeye G-032 TEC1 and Goldeye G-032 Cool TEC2, respectively.
•
Goldeye CL-008 models are available with single-stage temperature control in
both housing sizes. They are named Goldeye CL-008 TEC1 and Goldeye CL-008
Cool TEC1, respectively. Note that in this case it is impossible to distinguish
both models without naming the housing size.
Name affix for temperature control
Goldeye models that are equipped with the same sensor may be available with
different temperature controls. To make an unambiguous distinction possible, the
temperature control is denoted in the model name.
Note that
gives an overview of Goldeye model naming only. For more
detailed information on temperature control, refer to
Example
Goldeye CL-033 models are available with temperature stabilization and without
temperature control. Names of these models are Goldeye CL-033 TEC1 and
Goldeye CL-033 TECless, respectively. Note that it is impossible to distinguish both
models without naming the TEC stage.
Goldeye G frame rates
To achieve the highest possible frame rates for different formats, it may become
necessary to change the GigE streaming features, particularly to adjust the GigE
packet size.
•
Smaller packets may be advantageous if using small ROIs
•
Larger packets may be advantageous if using larger ROIs
Name affix
Description
TEC1
TEC1 models are equipped with a single-stage thermo-electric
temperature control.
TEC2
TEC2 models are equipped with dual-stage thermo-electric
cooling.
TECless
These models are not equipped with thermo-electric cooling.
Table 7: Distinction between Goldeye models with various TEC stages