Triggering
200
Goldeye G/CL Technical Manual V4.2.0
I/O definitions
External GND and external power
Goldeye standard models
Use pins 1 and 2 of the Hirose 12-pin connector to power
the camera:
•
Goldeye G/CL-008 TEC1
•
Goldeye G/CL-032 TEC1
•
Goldeye G/CL-033 TEC1, G/CL-033 TECless
•
Goldeye G/CL-034 TEC1
Goldeye Cool models
Use pin 1 to pin 4 of the Hirose 4-pin connector to supply
the camera with power:
•
Goldeye G/CL-008 Cool TEC1
•
Goldeye G/CL-032 Cool TEC2
For more information on power supply refer to
.
RxD RS232 and TxD RS232 (pin 8, pin 9)
These signals are RS232 compatible. These signals are not
optically isolated. Connect RS232 ground to Camera GND
to complete the RS232 circuit. Communication takes place
at a bandwidth of up to 115,200 bits per second (customer
adjustable).
Observe the input voltage
Exceeding the 30 V input voltage can permanently damage the camera.
More information on the RS232 interface
For complete RS232 description and usage on GigE cameras, see the application
note RS232 Port Explained on the Allied Vision knowledge base webpage:
www.alliedvision.com/en/support/technical-papers-knowledge-base.html