Triggering
204
Goldeye G/CL Technical Manual V4.2.0
Output signals
Output signals can be assigned to a variety of internal camera signals via software.
They can be configured to active high or active low. The internal camera signals are
listed in
.
Out 1 - non-isolated (pin 6)
The
Out 1
signal is not electrically isolated and can be used
when environmental electrical noise is inconsequential,
and faster trigger response is required. Connect signal
ground to
External GND
to complete the external circuit.
Output signal
Description
Exposing
Indicates when camera is integrating light.
Trigger Ready
Indicates when the camera is ready to accept a trigger signal.
Trigger Input
A relay of the trigger input signal used to “daisy chain” the
trigger signal for multiple cameras.
Readout
Valid when the camera is reading out data.
Imaging
Valid when the camera is exposing or reading out.
Strobe
Programmable pulse based on one of the events as listed.
GPO
User programmable binary output.
Figure 60: Goldeye G/CL internal camera signals
Signal
Output
Output signal
TTL (5 V)
Maximum output current
20 mA
Table 132: Output 1 output signal and maximum current
Possible low output voltage
Output voltage may drop
down to 3.5 V
under full load.
2
6
5
4
1
3
10
7
8
9
1
1
1
2
6